13. CHECKLIST FOR POLY URETHANE
(PU) MEMBRANE WATERPROOFING |
|||
Name Of Project : |
|||
Date of Checking: |
|||
Location / Structure: |
|||
Drawing / Document Reference No. |
|||
|
|||
Sl. |
Description / Activities / Items to
be Checked |
Status |
|
1 |
Check
for the safety process is followed for waterproofing activities. |
OK |
Not OK |
2 |
Check for approval of work methodology of waterproofing |
OK |
Not OK |
3 |
Check for approval of Waterproofing system and materials which to be
used. |
OK |
Not OK |
PRIOR TO APPLICATION |
|||
1 |
Check all the construction joints and surface defects of concrete is
repaired as per methodology. |
OK |
Not OK |
2 |
Check for filling up of tie rod holes with non-shrink cementitious
grout |
OK |
Not OK |
3 |
Check the primer is applied on concrete surface before application PU
coating. |
OK |
Not OK |
4 |
Check proper application of PU membrane & it's method of
application (Roller / Brush / Spray) |
OK |
Not OK |
5 |
Check proper joint at corner of the wall |
OK |
Not OK |
DURING APPLICATION |
|||
1 |
Check for the RCC surface moisture content (%) before application of
PU coat. |
OK |
Not OK |
2 |
Check for the proper mixing of PU
before application |
OK |
Not OK |
3 |
Check for the layer thickness of PU coat during and after application. |
OK |
Not OK |
4 |
Check for the consumption of PU as per coverage area. |
OK |
Not OK |
5 |
Check for the proper application and overlapping of roller/brush |
OK |
Not OK |
|
|
OK |
Not OK |
PROTECTION OF PU MEMBRANE |
|||
1 |
Check for the pull adhesion strength of PU (if required) |
OK |
Not OK |
2 |
Check laying of geo textile on PU surface before laying of screed
concrete. |
OK |
Not OK |
3 |
Check for the thickness of the screed concrete as per specification. |
OK |
Not OK |
4 |
Check and ensure no damages of PU membrane during application of
screeding. |
OK |
Not OK |
5 |
Check application of primer & sprinkling of sand for bonding with
plaster for protection of vertical surface of PU membrane. |
OK |
Not OK |
6 |
Check thickness of plaster layer for protection of vertical surface. |
OK |
Not OK |
Remark: |
13. CHECKLIST FOR POLY URETHANE (PU) MEMBRANE WATERPROOFING
Subscribe to:
Post Comments (Atom)
-
23. CHECKLIST FOR FIXING OF FALSE CEILING Name Of Project : Date of Checking: Location / ...
-
METHODOLOGY / PROCEDURE OF CONVENTIONAL SHUTTERING & CONCRETING WORK TERMINOLOGY OF FORMWORK : Ø Formwork (Shuttering ) ...
-
26. CHECKLIST FOR VDF / TREMIX FLOORING Name Of Project : Date of Checking: Location / Fl...
I really like reading your blog post.
ReplyDeletePU Coating paint