10. CHECKLIST
FOR CHEMICAL WATERPROOFING WITH
BRICK BAT |
|||
Name Of Project : |
|||
Date of Checking: |
|||
Location / Structure: |
|||
Drawing / Document Reference No. |
|||
|
|||
Sl. |
Description / Activities / Items to
be Checked |
Status |
|
1 |
Check
for the safety process is followed for waterproofing activities. |
OK |
Not OK |
2 |
Check for approval of work methodology of waterproofing |
OK |
Not OK |
3 |
Check for approval of Waterproofing system and Chemicals to be used. |
OK |
Not OK |
PRIOR TO CHEMICAL COATING |
|||
1 |
Check for Cleaning of bare slab like removal and cleaning of oil,
grease, dead concrete / mortar, dust, any exposed steel, wood pieces, etc. |
OK |
Not OK |
2 |
Check for Ponding test to be done for 24 hours to find any leakages |
OK |
Not OK |
3 |
Check for nozzle grouting is done by using of integral waterproof
compound with cement slurry if any leakage is observed during Pond test. |
OK |
Not OK |
4 |
Check for the making of corner batta / hunch filling by cement mortar
with mixing of integral waterproofing chemicals. |
OK |
Not OK |
5 |
Check for availability of material and tools as per procedure /method
statement. |
OK |
Not OK |
DURING APPLICATION OF WP CHEMICALS |
|||
1 |
Check and ensured that slab cleaned from dust and other particles |
OK |
Not OK |
2 |
Check Mixing of polymer base Chemical and cement with proper
proportions by mechanical stirrer as per manufacturer guidelines before ready
to use on substrate. |
OK |
Not OK |
3 |
Check application of 1 st coat of polymer base chemical on substrate
as per manufacturer guidelines. |
OK |
Not OK |
4 |
Check application of 2 nd coat or subsequent coat after 4hrs
perpendicular in the direction of 1st coat. |
OK |
Not OK |
5 |
Check chemical application minimum up to the required height as per
project specification. |
OK |
Not OK |
6 |
Check for the consumption of chemicals as per methodology. |
OK |
Not OK |
7 |
Check Sprinkling of sand over the 2nd coat of chemical for mechanical
bonding with protection coat of plaster. |
OK |
Not OK |
AFTER APPLICATION OF WP CHEMICAL |
|||
1 |
Check Pond Test for 48hrs after drying chemical coat. |
OK |
Not OK |
2 |
Ensure no leakage & damage on waterproof surface |
OK |
Not OK |
DURING BRICK BAT |
|||
1 |
Laying 15-20mm thick cement sand mortar of 1: and admixed with
integral waterproofing compound @200ml/bag of cement or as per manufacturer’s
guidelines as a base mortar for Brickbats |
OK |
Not OK |
2 |
Ensure laying min.75mm thick brick bats of varying sizes over the
mortar in a gradient of 1:150 with varying thickness as per site condition. |
OK |
Not OK |
3 |
Is the Brick bats pre-wetted before laying |
OK |
Not OK |
4 |
Is the minimum half portion of brickbats should be immersed in mortar
and staggered joint between two brickbats |
OK |
Not OK |
AFTER BRRICK BAT |
|||
1 |
Check the curing for 7days |
|
|
2 |
|
|
|
REMARKS: |
10. CHECKLIST FOR CHEMICAL WATERPROOFING WITH BRICK BAT
Subscribe to:
Post Comments (Atom)
-
23. CHECKLIST FOR FIXING OF FALSE CEILING Name Of Project : Date of Checking: Location / ...
-
METHODOLOGY / PROCEDURE OF CONVENTIONAL SHUTTERING & CONCRETING WORK TERMINOLOGY OF FORMWORK : Ø Formwork (Shuttering ) ...
-
26. CHECKLIST FOR VDF / TREMIX FLOORING Name Of Project : Date of Checking: Location / Fl...
Nice Blog! Are you looking for terrace waterproofing in Panchkula? We provide top-quality waterproofing services at a reasonable price. We provide customer satisfaction with our waterproofing services. We provide 100% permanent solutions for terraces and 24*7 available for our customers. Our well-qualified team uses different methods and technology for waterproofing work.
ReplyDelete