Pages

19. CHECKLIST FOR FIXING OF DOOR FRAME & DOOR SHUTTER

 

19. CHECKLIST FOR FIXING OF DOOR FRAME & DOOR SHUTTER

Name Of Project :

Date of Checking:

Location / Flat / Floor no:

Drawing / Document Reference No.

 

Sl.
No.

Description / Activities / Items to be Checked

Status

1

Check for the safety process is followed for fixing of door frame & door shutter.

OK

Not OK

 

 

 

 

PRIOR TO DOOR FRAME FIXING

1

Check for approval of work methodology for fixing of door frame & Door Shutter

OK

Not OK

2

Check for availability of Tool and tackles for fixing of door frame & Door Shutter

OK

Not OK

3

Check for density & moisture % of wooden door frame as per project specification

OK

Not OK

4

Check the shape & size of the door frame & shutter is made as per  architectural drawing

OK

Not OK

5

Check for the top level of the door frame is marked on the wall

OK

Not OK

FIXING OF DOOR FRAME

1

Check for vertical members of the door frames is rest on floor

OK

Not OK

2

Check the verticality of the door frame member

OK

Not OK

3

Check for right angle and diagonal alignment of the door frames

OK

Not OK

4

Check for plumb for the Door Frame w.r.t. Masonry Opening.

OK

Not OK

5

Check for the no. of anchor is used as per drawing

OK

Not OK

6

Check for fastening of door frames to Walls by Screws.

OK

Not OK

7

Check for grouting of holdfasts into wall (in case of holdfast is used)

OK

Not OK

FIXING OF WOOODEN DOOR SHUTTER

1

Check the type and size of shutter as per drawing.

OK

Not OK

2

Check for the provision and proper functioning of the door.

OK

Not OK

3

Check for the Finish of Door shutter as per specification.

OK

Not OK

4

Check for the Dimension of the shutter as per drawing.

OK

Not OK

5

Check for the door shutter is according to drawing, design and specification.

OK

Not OK

6

Check the shutter is not damaged and Laminate is fixed properly.

OK

Not OK

7

Check for the Finishing of shutter is up to the mark i.e. line, level and smoothness

OK

Not OK

8

Check size / brand / finishes of hardware fittings as per specification

OK

Not OK

9

Check for the screws are of proper size and tight with screwdriver not hammered

OK

Not OK

10

Check all fittings are fixed as per drawing / approved  architect / client

OK

Not OK

11

Check the alignment of the door shutter after fixing

OK

Not OK

12

Check the clearance between door shutter and frame as per drawing.

OK

Not OK

13

Check the clearance between door shutter and floor as per drawing.

OK

Not OK

14

Check for polish / paint works completed for door frame.

OK

Not OK

15

 

OK

Not OK

Remarks:

 


No comments: